Call us
Medical Departments
MRI
An imaging technique used to explore the anatomy and physiology of the body.
Model name: Magneton Siemens Avanto
Magnetic power: 1,5 Tesla (T)
Hole dimensions: 70 cm
Maximum Range: 45 mT/m
CT Scan
Examination method that shows the whole body in vertical sections, using X-rays.
Number of slices: 64
Model number: SOMATOM Smiens 64 Slice
Scan time: 100 scans/second
Permissible unit weight limit: <100kg
Suitable for people with claustrophobia
Fast examination with high definition
imaging and lower radiation doseSpecial diffusion sequences and
3D illustration of vases
X-Rays
An imaging technique that uses X-rays, which are getting through and absorbed by the human body.
All table and tube movements are made
and performed quickly and effortlesslyQuickly placement of the table at the most convenient height,
making it easy to access for the disabled, stretchers
older patients, and childrenMoviplan 800 system is equipped
with high frequency generators
with power levels from 32 to 80kWBuilt-in APR (Anatomy Programs)
to reduce configuration times and maximize your workflowAlso available as options are both Automatic
exposure control (AEC) and the high-speed booter
Dexa
Double energy absorption method for the definition of bone density at any point in the human skeleton.
60 seconds per site
4 minutes for the whole body
FRAX tool for the patient fracture risk assessment
Morphometric tools that help assess fracture risk
using morphological parameters such as angle and distance
Mammography
The digital method of analog mammograms uses a digitizer and the use of phosphor cartridges, to produce a digital image.
Manufacturer specifications:
Senographe DMR, GE HealthcareType of mammogram machine equipment:
MODEL Senographer DMR GEX-ray release options Control console, Hand switch
Small Focal points 0.1 mm
Large Focal points 0.3 mm
Dimensions (HXWXD) CM:
(IN) (DISPLAY) 171x55x122 (67,2x21,6x48)
WEIGHT, kg (lb) (DISPLAY) 280 (617), column
3Dx Panoramic
High definition imaging, with minimization of radiation doses for more effective diagnosis and treatment.
Scan time: 18 - 34 s
Effective exposure time: 2,4 - 6 s
Image slot type: 3D Flat panel a-Si
X-ray generator
Focal point 0.5 mm
Goal angle 15 degrees
U/S - Triplex Scan
An imaging method that produces images of human body organs by using ultrasound.
It has a large screen LCD 21,5
10.4 touch screen and customizable shortcuts
Supports 13 transducers covering frequencies
up to 16MHz (linear), and optical fields up to 220 °
(intra-abdominal, wide angle)Supports a large linear fingerprint converter
(larger than 50mm) and a small hockey
linear fingerprint converter
Biopsies
A diagnostic method that examines tissues both microscopically and under a microscope for the causes of a disease.
Thyroid and Breast
Immediate diagnostic direction
Histological Examinations
Cytological Examinations
Molecular Analyses